Confidence in Brachytherapy Source Calibration 

Thousands of centers and many leading institutions worldwide have chosen  

Standard Imaging instruments for precise high-dose rate, low-dose rate  

and intravascular brachytherapy calibrations – find out why. 

*from US News and World Report 

Why perform independent verification? 

• Although source manufacturers have high  

standards, an independent check of the source  

strength allows physicists to ultimately determine  

if a source is safe and appropriate for treatment. 

• AAPM TG-56, TG-40 and TRS-398 recommend  

independent verification of source strength. 

• Without independent calibration, centers in the  

U.S. may miss out on reimbursement income. 

• IAEA has Standard Imaging well chambers in all  

of its standards labs. 

HDR 1000 PLUS WELL CHAMBER 

• Validated in over 50 scientific presentations  

and trusted by radiation standards laboratories  

worldwide. 

• The HDR 1000 Plus Well Chamber is an  

air-communicating chamber, so there is no  

inaccuracy due to undetected gas leaks. 

IVB 1000 WELL CHAMBER 

The IVB 1000 Well Chamber has an active length four  

times longer than the HDR 1000 Plus, making it ideal  

for long source trains. IVB 1000 Well Chamber HDR 1000 Plus Well Chamber

High Dose Rate Low Dose Rate 

HDR 192Ir Sources 

The high dose rate  

192Ir source holder  

has a rubber O-ring  that prevents catheter  movement. Calibration is  easy, requiring a fraction  of the time of thimble ion  chamber techniques. 

HDR ref 70010 

IVB ref 70044 

BEBIG 60Co and  192Ir Afterloader 

For use with the BEBIG  Remote Afterloader  source catheters.  

The source holder is  calibrated at the factory HDR ref 70110 

Leipzig Applicator 

Perform output  

verification of the  

Leipzig & Valencia HDR  applicators used with  microSelectron  

- HDR “Classic”  

and v2 afterloaders.  

HDR ref 70031 

HDR 192Ir Quality  Assurance Tool 

Perform crucial tests of  192Ir sources, including  source positioning  

(within 0.3 mm), timer  accuracy and consistency  of source activity. 

HDR ref 70008 

137Cs Sources 

Commonly used with  manually loaded 137Cs  sources, this source  holder has a 5.0 mm  diameter opening. The  spacer for positioning the  137Cs source is removable  for use with longer 137Cs  sources and larger  

HDR 192Ir catheters. 

HDR ref 70020 

IVB ref 70045 

Syringe Holders 

Quick, convenient  

measurements of  

METASTRON® 89Sr,  153Sm, 223Ra and 131I vials  and most liquids in a 5 cc  or 10 cc syringe. Includes  one 5 cc syringe and one  10 cc syringe. 

Nucletron microSelectron  HDR Sources 

Connects directly to  

the couple of the HDR  

afterloader for output  

measurements with the  

Nucletron system. 

HDR ref 72280 

137Cs Remote  

Afterloading Sources Designed for use with  

LDR remote after 

loading treatment  

systems, this source  

holder has a 7.1 mm  

diameter opening.  

There is no spacer because  

the after-loading system  

positions the source. 

HDR ref 70003 

IVB ref 70046 

Single LDR Seed Sources 

1.2 mm inner diameter  

tube positions individual  

seeds at the most  

sensitive area of the  

well chamber.  

HDR ref 70016 

IVB ref 70043 

Seed Batch Assay Tool 

Multiple measurements  

for up to 500 iodine or  

palladium seeds. 

HDR ref 70022 

Preloaded Needle Sources 

• Facilitates calibration  

and visual verification  

of a sterilized needle  

filled with seeds  

and spacers. 

• A universal luer  

lock offers seamless  

integration from seeds  

Mick® Cartridge Sources 

The Mick® Cartridge  

source holder provides a  

consistency check of seed  

activity. A source holder  

positions the cartridge  

for a quick, reproducible  

measurement. 

HDR ref 70024 

IVB ref 70047 

RAPID Strand® 125I  Seed Sources 

The RAPID Strand®  

iodine seed source holder  

provides a convenient,  

sterile method to perform  

a quality assurance  

measurement of the  

125I RAPID Strand®. 

HDR ref 70023 

IVB ref 70048 

192Ir Pin 

Repeatable QA  

measurements with  

three different sized 192Ir  

wire pins such as models  

IRF-1, IRF-2, IREC-2 and  

IREL-2.  

HDR ref 70095 

Bard QuickLink/MICK  

Measure the source  

output strength of seeds  

within the QuickLink or  

MICK cartridge pack,  

without removing the  

sterile packaging.  

HDR ref 72307 

Nucletron selectSeed™  Sources 

The Nucletron  

seedSelectron™ centers a  

source in the active area  

of the HDR 1000 Plus  

Well Chamber. 

HDR ref 70030 

LDR 192I Sources 

Position sources in  

the active area of the  

HDR 1000 Plus and  

IVB 1000 Well Chamber  

for measurement.  

IVB ref 70009 

IVB ref 70031 HDR ref 70026 IVB ref 70026 

to the needle. IVB ref 70051

Source Holder Product Matrix

Source Holder HDR ref IVB ref Isotope ADCL Calibration available 

HDR 1000 PLUS WELL CHAMBER (REF 90008) SPECIFICATIONS 

HDR 192Ir Sources 70010 70044 HDR 192Ir Yes HDR 192Ir Quality Assurance Tool 70008 HDR 192Ir No BEBIG 60Co and 192Ir Afterloader 70110 60Co, HDR 192Ir SSDL 137Cs Sources [5mm] 70020 70045 137Cs Yes 137Cs Remote Afterloading Sources [7.1mm] 70003 70046 137Cs Yes Nucletron microSelectron HDR Sources 72280 125I Yes Leipzig Applicator 70031 70031 HDR 192Ir No Syringe Holders 70026 70026 Metastron, 89Sr, 153Sm, 131I, 223Ra No Preloaded Needle Sources 70051 125I, 103Pd No RAPID Strand® Iodine Seed Sources 70023 70048 125I No Nucletron selectSeed™ Sources 70030 125I Yes Single LDR Seed Sources 70016 70043 192Ir, 125I, 103Pd, 131Cs Yes 

ADCL CALIBRATIONS HDR 192Ir and/or LDR radionuclides from various manufacturers as requested 

ACTIVE VOLUME 245 cm3 

CONNECTOR Two lug triax BNC (standard) 

TNC, Type M, or BNC + Banana (optional) 

RANGE 10 U to 80 MU 0.01 mCi to 20 Ci CABLE 3 ft, 1 m 

BIAS VOLTAGE ± 300 volts, typical 

LEAKAGE Less than 50 fA 

STABILITY 0.2% (Reproducibility over 2 years)  RESPONSE ± 0.5% over 25 mm at center of axis 

SENSITIVITY 

SOURCE Current to Air Kerma Strength Current to Apparent Activity (U=1uGym2/h) 

HDR Iridium: 2.1 pA/U 8.6 nA/Ci Cesium: 2.0 pA/U 5.6 nA/Ci LDR Iridium: 2.3 pA/U 9.1 nA/Ci Iodine: 4.3 pA/U 5.4 nA/Ci Palladium: 2.1 pA/U 2.4 nA/Ci 

Aion 0.9996, typical 

ACCESSORIES Case (REF 50004) 

Wall mount accessory (REF 70007) 

(5) Interlocking 1” lead rings (REF 70125) 

Carrying case for any Comprehensive Calibration System  

(REF 70012) 

DIMENSIONS Height: 6.1 in, 15.6 cm Insert Diameter: 1.4 in, 3.5 cm Diameter: 4 in, 10.2 cm Insert Height: 4.8 in, 12.1 cm 

Weight: 6.1 lbs, 2.7 kg 

Specifications subject to change without notice. 

192Ir Pin 70095 192Ir Yes 

IVB 1000 WELL CHAMBER (REF 90009) SPECIFICATIONS 

Seed Batch Assay Tool 70022 125I, 103Pd No LDR 192Ir Sources 70009 LDR 192Ir Yes Mick® Cartridge Sources 70024 70047 125I, 103Pd No Bard QuickLink/MICK 72307 125I, 103Pd No Xoft Electronic Brachytherapy 70088 Electronic Yes 

NOTE: One source holder may have several calibrations associated with it. For example, a source holder for Single LDR Seeds  (REF 70016 and 70043) may have calibrations for iodine, palladium and LDR iridium. 

ACTIVE VOLUME 475 cm3 

CONNECTOR Two lug triax BNC (standard) 

TNC, Type M, or BNC + Banana (optional) 

RANGE 10 U to 80 MU 0.01 mCi to 20 Ci CABLE 3 ft, 1 m 

BIAS VOLTAGE ± 300 volts, typical 

LEAKAGE Less than 50 fA 

STABILITY 0.2% (Reproducibility over 2 years)  RESPONSE ± 0.3% over 100 mm at center of axis, typical 

SENSITIVITY 

SOURCE Current to Air Kerma Strength Current to Apparent Activity (U=1uGym2/h) 

HDR Iridium: 2.2 pA/U 9.0 nA/Ci Cesium: 2.1 pA/U 5.9 nA/Ci LDR Iridium: 2.4 pA/U 9.5 nA/Ci Iodine: 4.3 pA/U 5.5 nA/Ci Palladium: 2.3 pA/U 2.6 nA/Ci 

Approx. 38.5 nA/Gy/s for 90Sr/90

ACCESSORIES Case (REF 50026) included 

(4) Interlocking 1” lead rings (REF 70025) 

Carrying case for Comprehensive Calibration System  

(REF 70012) 

DIMENSIONS Height: 10.2 in, 25.9 cm Insert Diameter: 1.4 in, 3.5 cm Diameter: 4 in, 10.2 cm Insert Height: 8.8 in, 22.4 cm 

Weight: 8.0 lbs, 3.6 kg 

Specifications subject to change without notice. 

www.standardimaging.com 

800-261-4446 . ph 608-831-0025 . fax 608-831-2202 3120 Deming Way Middleton WI 53562-1461 USA 

© 2016 Standard Imaging, Inc. 1235-24 (11.16)